L-751
Woven Epoxy Laminating Prepreg, Aramid
Click For
Page 1
Page 2
Mechanical Data

 

LAMINATE PROPERTIES

PROPERTY

30 PSI (0.24 MPa) CURE

VACUUM BAG CURE

TEST METHOD

ULTIMATE TENSILE STRENGTH

 

 

 

Room Temperature (RT)

69 KSI (476 MPa)

67 KSI (462 MPa)

ASTM D638

160°F (71°C)

61 KSI (421 MPa)

59 KSI (407 MPa)

ASTM D638

RT(WET)

67 KSI (462 MPa)

64 KSI (441 MPa)

ASTM D638

 

 

 

 

TENSILE MODULUS

 

 

 

Room Temperature (RT)

3.9 MSI (27 GPa)

3.8 MSI (26 GPa)

ASTM D638

160°F (71°C)

3.4 MSI (23 GPa)

3.3 MSI (23 GPa)

ASTM D638

RT(WET)

3.7 MSI (26 GPa)

3.6 MSI (25 GPa)

ASTM D638

 

 

 

 

ULTIMATE COMPRESSION STRENGTH

 

 

 

Room Temperature (RT)

22 KSI (152 MPa)

21 KSI (145 MPa)

ASTM D695

160°F (71°C)

16 KSI (110 MPa)

15 KSI (103 MPa)

ASTM D695

RT(WET)

21 KSI (145 MPa)

20 KSI (138 MPa)

ASTM D695

 

 

 

 

COMPRESSION MODULUS

 

 

 

Room Temperature (RT)

3.0 MSI (21 GPa)

2.9 MSI (20 GPa)

ASTM D695

160°F (71°C)

2.9 MSI (20 GPa)

2.7 MSI (19 GPa)

ASTM D695

RT(WET)

2.9 MSI (20 GPa)

2.7 MSI (19 GPa)

ASTM D695

 

 

 

 

ULTIMATE FLEXURAL STRENGTH

 

 

 

Room Temperature (RT)

44 KSI (303 MPa)

42 KSI (290 MPa)

ASTM D790

160°F (71°C)

23 KSI (159 MPa)

21 KSI (145 MPa)

ASTM D790

 

 

 

 

FLEXURAL MODULUS

 

 

 

Room Temperature (RT)

3.1 MSI (21 GPa)

3.0 MSI (21 GPa)

ASTM D790

160°F (71°C)

3.0 MSI (21 GPa)

2.9 MSI (20 GPa)

ASTM D790

 

 

 

 

INTERLAMINAR SHEAR STRENGTH

 

 

 

Room Temperature (RT)

2.7 KSI (19 MPa)

2.6 KSI (18 MPa)

ASTM D2344

 

 

 

 

  
Click For Page 1 Page 2

NOTICE:Product data and parameters cited in this publication have been obtained in J.D. Lincoln, Inc. laboratories using the materials under carefully controlled conditions. The information, therefore, is believed to be accurate and correctly stated. Data of this type may be considered to be indicative of representative properties obtainable. J.D. Lincoln, Inc. cannot accept responsibility for the misapplication of these products, nor for their use under uncontrolled conditions. Numerical values resulting from the application of this material are dependant on processing details. It is recommended that the user develop his or her own application techniques and generate data consistent with his or her specific application and process.

 
       
Website Copyright 1996-2008 by J.D. Lincoln Inc.
A Member of the Umeco Plc Group.