Tested per MIL-R-7575C Grade A |
Test Method |
Requirement |
Average |
Flexural Strength |
ASTM D790 |
50.0 ksi (345 MPa) |
91.5 ksi (631 MPa) |
Flexural Modulus |
ASTM D790 |
2.7 msi (19 GPa) |
3.3 msi (23 GPa) |
Tensile Strength |
ASTM D638 |
40.0 ksi (276 MPa) |
61.6 ksi (425 MPa) |
Compressive Strength |
ASTM D695 |
35.0 ksi (241 MPa) |
60.1 ksi (414 MPa) |
Flammability (inch/min) |
ASTM D635 |
1.0 (max) |
did not reach reference |
Water Absorption, 24 hr soak, % wt change |
ASTM D570 |
+0.5 (max) |
0.04 |
Barcol Hardness |
see 4.6.4 |
55 |
81 |
Specific Gravity |
ASTM D792 |
report |
2.079 |
Resin Content (%) |
ASTM C613 |
report |
32.4 |
Tested Wet - Flexural Strength |
ASTM D790 |
45.0 ksi (310 MPa) |
85.4 ksi (589 MPa) |
Tested Wet - Flexural Modulus |
ASTM D790 |
2.5 msi (17 GPa) |
3.6 msi (25 GPa) |
Tested Wet - Tensile Strength |
ASTM D638 |
38.0 ksi (262 MPa) |
62.1 ksi (428 MPa) |
Tested Wet - Compressive Strength |
ASTM D695 |
30.0 ksi (207 MPa) |
56.9 ksi (392 MPa) |
Tested @ 156°F (70°C) - Flexural Strength |
ASTM D790 |
40.0 ksi (276 MPa) |
48.8 ksi (337 MPa) |
Tested @ 156°F (70°C) - Flexural Modulus |
ASTM D790 |
2.3 msi (16 GPa) |
2.6 msi (18 GPa) |
MIL-H-5606 Hydraulic Fluid (24 hr soak at RT) |
|
|
% change in wt / % change in thickness |
ASTM D543 |
0.2 (max) |
0.04 / 0 |
Flexural Strength |
ASTM D790 |
report |
93.9 ksi (648 MPa) |
TT-I-735 Isopropyl Alcohol (24 hr soak at RT) |
|
|
% change in wt / % change in thickness |
ASTM D543 |
0.1 (max) |
0.03 / 0 |
Flexural Strength |
ASTM D790 |
report |
88.7 ksi (612 MPa) |
TT-S-735 Standard Test Fluids, Hydrocarbon, Type III (24 hr soak at RT) |
|
% change in wt / % change in thickness |
ASTM D543 |
0.1 (max) |
0.06 / 0 |
Flexural Strength |
ASTM D790 |
report |
96.9 ksi (668 GPa) |