L-530
Solution Coated Epoxy Prepreg
Click For
Page 1
  Sandwich Properties*
Core: Aramid Phenolic, 3 lbs/ft3, 1/8” cell (16 kg/m3, 3.175 mm)
Facings: 1 ply L-530-7781 each side
  • RT Flatwise Tensile Strength: Core Failure
  • RT Sandwich Peel Strength: 15 in lb/in (67 N/25 mm)
  • *Sandwich peel strength varies with orientation of fibers directly against the core and test direction.
  • Fibers laid up parallel with the test direction produce minimum strengths.
  • Fibers laid up perpendicular to the test direction produce maximum strengths.
  Mechanical Data

Property

Vacuum Pressure

Test Method

Ultimate Tensile Strength

 

 

Room Temperature (RT)

61 KSI (421 MPa)

ASTM D638

160°F (71°C)

45 KSI (310 MPa)

ASTM D638

RT after 1 Hour Water Boil

57 KSI (393 MPa)

ASTM D638

Tensile Modulus

 

 

Room Temperature (RT)

3.5 MSI (24 GPa)

ASTM D638

160°F (71°C)

3.5 MSI (24 GPa)

ASTM D638

RT (Wet)

3.5 MSI (24 GPa)

ASTM D638

Ultimate Compression Strength

 

 

Room Temperature (RT)

68 KSI (469 MPa)

ASTM D695

RT after 1 Hour Water Boil

56 KSI (386 MPa)

ASTM D695

Compression Modulus

 

 

Room Temperature (RT)

3.5 MSI (24 GPa)

ASTM D695

RT (Wet)

3.4 MSI (23 GPa)

ASTM D695

Ultimate Flexural Strength

 

 

Room Temperature (RT)

96 KSI (662 MPa)

ASTM D790

160°F (71°C) after 30 Minute Soak @ 160°F

74 KSI (510 MPa)

ASTM D790

RT after 1 Hour Water Boil

80 KSI (552 MPa)

ASTM D790

RT after 30 day Hydraulic Fluid Soak

78 KSI (538 MPa)

ASTM D790

RT after 30 day JP-4 Fuel Soak

78 KSI (538 MPa)

ASTM D790

Flexural Modulus

 

 

Room Temperature (RT)

3.6 MSI (25 GPa)

ASTM D790

160°F (71°C)

3.5 MSI (24 GPa)

ASTM D790

  

NOTICE:Product data and parameters cited in this publication have been obtained in J.D. Lincoln, Inc. laboratories using the materials under carefully controlled conditions. The information, therefore, is believed to be accurate and correctly stated. Data of this type may be considered to be indicative of representative properties obtainable. J.D. Lincoln, Inc. cannot accept responsibility for the misapplication of these products, nor for their use under uncontrolled conditions. Numerical values resulting from the application of this material are dependant on processing details. It is recommended that the user develop his or her own application techniques and generate data consistent with his or her specific application and process.

 
       