  Mechanical Properties: 0.060 lbs/ft2 (292 g/m2) Adhesive Film

Property

25 PSI (0.17 MPa) Cure in Platen Press

Press Cure after 1 Month Outlife

Test Method

 

 

 

 

Tensile Shear Strength

 

 

 

-67°F (-55°C)

6,700 PSI (46.2 MPa)

6,680 PSI (46.0 MPa)

ASTM D1002

Room Temp

5,900 PSI (40.6 MPa)

5,950 PSI (41.0 MPa)

ASTM D1002

180°F (82°C)

4,600 PSI (31.6 MPa)

4,500 PSI (31.0 MPa)

ASTM D1002

250°F (121°C)

2,250 PSI (15.5 MPa)

2,000 PSI (13.8 MPa)

ASTM D1002

 

 

 

 

Sandwich Peel Strength

 

 

 

-67°F (-55°C)

42 in lb/in (187 N/25mm)

40 in lb/in (178 N/25 mm)

ASTM D1781

Room Temp

39 in lb/in (173 N/25mm)

35 in lb/in (156 N/25 mm)

ASTM D1781

180°F (82°C)

35 in lb/in (156 N/25 mm)

32 in lb/in (142 N/25 mm)

ASTM D1781

 

 

 

 

Flatwise Tensile Strength

 

 

 

-67°F (-55°C)

1,250 PSI (8.6 MPa)

1,140 PSI (7.9 MPa)

ASTM C297

Room Temp

1,120 PSI (7.7 MPa)

1,100 PSI (7.6 MPa)

ASTM C297

180°F (82°C)

660 PSI (4.5 MPa)

620 PSI (4.3 MPa)

ASTM C297

 

 

 

 

Sandwich Flexural Strength

 

 

 

-67°F (-55°C)

core failure

core failure

ASTM C393

Room Temp

core failure

core failure

ASTM C393

180°F (82°C)

core failure

core failure

ASTM C393

 

 

 

 

T-Peel Strength

 

 

 

-67°F (-55°C)

52 in lb/in (231 N/25 mm)

50 in lb/in (223 N/25 mm)

ASTM D1876

Room Temp

49 in lb/in (218 N/25 mm)

47 in lb/in (209 N/25 mm)

ASTM D1876

180°F (82°C)

41 in lb/in (182 N/25 mm)

40 in lb/in (178 N/25 mm)

ASTM D1876

 

 

 

 

Floating Roller Peel Strength

 

 

 

-67°F (-55°C)

105 in lb/in (467 N/25mm)

104 in lb/in (463 N/25 mm)

ASTM D3167

Room Temp

95 in lb/in (423 N/25 mm)

94 in lb/in (418 N/25 mm)

ASTM D3167

180°F (82°C)

85 in lb/in (378 N/25 mm)

82 in lb/in (365 N/25 mm)

ASTM D3167

Click For
Page 1 | Page 2

NOTICE:Product data and parameters cited in this publication have been obtained in J.D. Lincoln, Inc. laboratories using the materials under carefully controlled conditions. The information, therefore, is believed to be accurate and correctly stated. Data of this type may be considered to be indicative of representative properties obtainable. J.D. Lincoln, Inc. cannot accept responsibility for the misapplication of these products, nor for their use under uncontrolled conditions. Numerical values resulting from the application of this material are dependant on processing details. It is recommended that the user develop his or her own application techniques and generate data consistent with his or her specific application and process.

 
       