L-311
Foaming Film Adhesives - Core Splice
Click For
Page 1
  Cure Cycles
  • 15 minutes at 350°F (176°C), or
  • 40 minutes at 275°F (135°C), or
  • 60 minutes at 250°F (121°C), or
  • 90 minutes at 235°F (113°C).
Average Mechanical Properties
Core Shear Strength using 0.500” Thickness, 1/8” cell (1.27 cm, 3.18 mm) 5052 Al per Mil-C-7438

  • -67°F (-55°C) 780 PSI (5.4 MPa)
  • RT 810 PSI (5.6 MPa)
  • 180°F (82°C) 780 PSI (5.4 MPa)

Tube Shear Strength using 5052 Aluminum, 1.0” (2.54 cm) outer diameter, 0.5” (1.27 cm) inner diameter, 0.049” (1.25 mm) thickness Aluminum tubing.

  • RT 1310 PSI (9.0 MPa)
 
Note: L-311 should be allowed to reach room temperature before removing from protective packaging to avoid moisture condensation on the film surface.

NOTICE:Product data and parameters cited in this publication have been obtained in J.D. Lincoln, Inc. laboratories using the materials under carefully controlled conditions. The information, therefore, is believed to be accurate and correctly stated. Data of this type may be considered to be indicative of representative properties obtainable. J.D. Lincoln, Inc. cannot accept responsibility for the misapplication of these products, nor for their use under uncontrolled conditions. Numerical values resulting from the application of this material are dependant on processing details. It is recommended that the user develop his or her own application techniques and generate data consistent with his or her specific application and process.

 
       